DESCRIPTION
Model
n2xsy 12/20kV

Medium voltage single core cable 12/20 kV, XLPE insulated, PVC sheathed, with screen of Cu conductors

Application

Medium voltage power cable for static application in ground, within and outside facilities, outdoor, in cable canals, in water, in conditions where cables are not exposed to heavier mechanical stress and tensile strain. Due to its very low factor of dielectric loss, which remains constant over its entire operating lifetime, and owing to excellent insulation property of XLPE-material, firmly longitudinally spliced with inner and external screen of semi-conductive material (extruded in one process), the cable has a high operating reliability. Used in transformer stations, switching blocks, in electric power plants and industrial plants. To avoid the effects of external impact, the adhering semi-conductive layer extruded between conductor and insulation, along with concentric copper conductor, secures restriction of electric field and resistance to partial discharges.

Standards

HRN HD 620 S1
IEC 60502-2
DIN VDE 0276 part 620

Construction

Conductor: Cu round conductor, multi wire stranded compacted (RM), class 2
Inner screen: extruded semi-conductive skin on conductor
Insulation: XLPE (cross-linked polyethylene) compound
External screen: extruded semi-conductive skin on insulation, longitudinally spliced with insulation (+ tape of conductive material)
Concentric conductor: in inner layer corrugated spirally wrapped copper wires, in external layer copper tape wrapped in counter-helix
Separating tape
Sheath: PVC compound DMV-6 acc. to HRN HD 620 S1
sheath colour: red

 

Technical data

Temperature range:  
during installation: -5 °C up to +70 °C
max. operating temp.: +90 °C
at short circuit of max. 5 s: up to 250 °C
Minimal inner bending radius: 15D

 

Dimensions – number of cores x conductor cross-section Construction Conductor diameter Insulation thickness External diameter External diameter Conductor resistance at 20 °C Short circuit current 1s Cu weight Cable weight
    max. nominal min. max. max. nominal   prib.
N x mm²   mm mm mm mm Ω/km A kg/km kg/km
12/20 kV
1 x 35/16 RM 7,5 5,5 27 32 0,524 5,00 518 1067
1 x 50/16 RM 8,6 5,5 28 33 0,387 7,15 662 1208
1 x 70/16 RM 10,2 5,5 30 35 0,268 10,0 854 1446
1 x 95/16 RM 12,0 5,5 31 36 0,193 13,6 1094 1726
1 x 120/16 RM 13,5 5,5 33 38 0,153 17,2 1334 1983
1 x 150/16 RM 15,0 5,5 34 39 0,124 21,4 1622 2300
1 x 150/25 RM 15,0 5,5 34 39 0,124 21,4 1723 2353
1 x 185/16 RM 16,8 5,5 36 41 0,0991 26,5 1958 2650
1 x 185/25 RM 16,8 5,5 36 41 0,0991 26,5 2059 2712
1 x 240/16 RM 19,2 5,5 39 44 0,0754 34,3 2486 3250
1 x 240/25 RM 19,2 5,5 39 44 0,0754 34,3 2587 3290
1 x 300/25 RM 21,6 5,5 41 46 0,0601 42,9 3163 3889
1 x 400/35 RM 24,6 5,5 44 49 0,0470 57,2 4234 4831
1 x 500/35 RM 27,6 5,5 47 52 0,0366 71,5 5194 6050
1 x 630/35 RM 31,5 5,5 51 55 0,0283 90,1 6395 7340

 