DESCRIPTION
Model
NAYY

NAYY

Power cable 0,6/1 kV, PVC insulated and sheathed, with Al conductors

Application

Distribution power cable for static outdoor application (with protection against direct UV-irradiation), in ground, in water, within facilities, in cable canals, in concrete, in conditions where heavier mechanical loads and specially tensile strains, are not expected. Used in industrial plants, metropolitan networks and in other electric plants.

Standards

HRN HD 603 S1
IEC 60502-1
DIN VDE 0276 part 603

Construction

Conductor: Al, class 1 or 2
class 1: solid, round(RE) or sector (SE)
class 2: multi wire stranded, round (RM) or sector (SM)
Insulation: PVC compound , with or without protective yellow-green conductor
Filler: extruded elastomer or plastomer compound or wrapped thermoplastic tapes
Sheath: PVC compound
sheath colour: black

Technical data

Temperature range:
during installation: -5 °C up to +50 °C
fixed installed: -30 °C up to +70 °C
at short circuit of max. 5 s: up to 160 °C
Nominal voltage: Uο/U = 0,6/1 kV
Test voltage: 4 kV
Max. operating voltage in three-phase systems: 1,2 kV
Maximal tensile strength: 30 N/mm²
Behaviour in fire: IEC 60332-1
Minimal inner bending radius:
single core: 15D
multi core: 12D

 

Dimensions – number of cores x conductor cross-section Construction External diameter Insulation thickness Sheath thickness Conductor resistance at 20 °C Short circuit current 1s Cu weight Cable weight
    min - max. nom. nom. max. nom.   prib.
N x mm²   mm mm mm Ω/km kA kg/km kg/km
1 x 50 RM 14 - 17 1,4 1,8 0,641 3,80 - 298
1 x 70 RM 16 - 19 1,4 1,8 0,443 5,32 - 383
1 x 95 RM 18 - 21 1,6 1,8 0,320 7,22 - 490
1 x 120 RM 19 - 22 1,6 1,8 0,253 9,12 - 575
1 x 150 RM 21 - 25 1,8 1,8 0,206 11,40 - 695
1 x 185 RM 23 - 27 2,0 1,8 0,164 14,10 - 845
1 x 240 RM 26 - 30 2,2 1,8 0,125 18,20 - 1100
1 x 300 RM 28 - 32 2,4 1,9 0,100 22,80 - 1379
1 x 400 RM 32 - 37 2,6 2,0 0,0778 27,20 - 1615
1 x 500 RM 35 - 40 2,8 2,1 0,0605 34,00 - 2015
1 x 630 RM 41 - 45 2,8 2,2 0,0469 42,84 - 2472
4 x 16 RE 21 - 25 1,0 1,8 1,91 1,21 - 750
4 x 25 RE, RM 25 - 32 1,2 1,8 1,200 1,90 - 950
4 x 35 RE, SM 27 - 34 1,2 1,8 0,868 2,66 - 1141
4 x 50 SE, SM 29 - 36 1,4 1,9 0,641 3,80 - 1242
4 x 70 SE, SM 33 - 40 1,4 2,1 0,443 5,32 - 1631
4 x 95 SE, RM 38 - 45 1,6 2,2 0,320 7,22 - 2063
4 x 120 SE, SM 41 - 49 1,6 2,4 0,253 9,12 - 2538
4 x 150 SE, SM 46 - 54 1,8 2,5 0,206 11,40 - 3090
4 x 185 SE, SM 51 - 59 2,0 2,7 0,164 14,10 - 3838
4 x 240 SE, SM 57 - 65 2,2 2,9 0,125 18,20 - 4863
4 x 16+2,5 RM+RE 21,6 1,0 1,8 1,91 1,21 24 781
4 x 25+2,5 RM+RE 28 1,2 1,8 1,200 1,90 24 981
4 x 35+2,5 SM+RE 31 1,2 1,8 0,868 2,66 24 1172
4 x 50+2,5 SM+RE 35 1,4 1,9 0,641 3,80 24 1273
4 x 70+2,5 SM+RE 38 1,4 2,1 0,443 5,32 24 1662
4 x 95+2,5 SM+RE 42 1,6 2,2 0,320 7,22 24 2094
4 x 120+2,5 SM+RE 46 1,6 2,4 0,253 9,12 24 2569
4 x 150+2,5 SM+RE 49 1,8 2,5 0,206 11,40 24 3121
4 x 185+2,5 SM+RE 54 2,0 2,7 0,164 14,10 24 3869
4 x 240+2,5 SM+RE 59 2,2 2,9 0,125 18,20 24 4894

*) Packing: CUT = cable in different lengths on drum or reel, possible cutting at required length