XLPE Insulated and Bunched Aluminium ABC Cable - NFA2X

PRODUCTS

Product Name

XLPE Insulated and Bunched Aluminium ABC Cable - NFA2X

Page view
没有此类产品
Inquiry
Booking
Sample Application
DESCRIPTION
Model
0012

XLPE Insulated and Bunched Aluminium ABC Cable - NFA2X

XLPE Insulated and Bunched Aluminium Distribution 'Facade'Cables 600/1000V


STANDARDS

National : UTE 33-209


DESCRIPTION CONSTRUCTION:

All aluminium conductor

XLPE-insulation

ABBREVIATION:

N - Standard Cable type

F - Facade Cable

A - Aluminium conductor

2X - XLPE insulation

+N - with 'Messenger' Core

Round stranded Conductor for all sizes

connection derived from the distribution system.

APPLICATION:

For use in low voltage distribution system intended for urban and rural electrification schemes, for consumer connection derived from the distribution system.

CONSTRUCTION CHARACTERISTICS
Insulation XLPE (Cross-linked Polyethylene)
ELECTRICAL CHARACTERISTICS
Rated Voltage Uo/U (Um) 0.6/1 kV
USAGE CHARACTERISTICS
Maximum operating temperature 90°C
Bending factor when laying 10(xD)
Minimum installation temperature 90°C
Max. conductor temperature in service 90°C
Short-circuit max. conductor temperature 250°C

AVAILABLE BUNCHED ALUMINIUM CABLES

XLPE Insulated and Bunched Aluminium Distribution 'Facade' Cables, 0.6/1kV

Nominal 
Cross Sectional
Area

Number and 
Diameter of Wire

Nominal 
Overall 
Diameter

Maximum 
Current 
Rating

Standard 
Delivery 
Length

Weight 
per Standard 
Delivery L

Delivery 
on Wooden 
Drum

mm²

No x mm

mm

In Air @ 30°C

m

kg

 

2 - CORES (without messenger) Type: NFA2X

16

7 x 1.70

15

91

2000

275

R12

25

7 x 2.14

18.4

108

2500

531

R14

35

7 x 2.52

21.6

135

2500

583

R16

4 - CORES (without messenger) Type: NFA2X

16

7 x 1.70

18.1

77

2500

688

R14

25

7 x 2.14

22.2

97

2000

849

R16

35

7 x 2.52

26.1

120

1000

584

R16

4 - CORES (with messenger) Type: NFA2X + N

50/56.3

19 x 1.78 ALU

29.2

146

1000

811

R16

6 x 3.20 ALU + 1 x 3.20 St

70/56.3

19 x 2.14 ALU

34.5

187

500

521

R14

6 x 3.20 ALU + 1 x 3.20 St

95/56.3

19 x 2.52 ALU

39.1

227

500

649

R16

6 x 3.20 ALU + 1 x 3.20 St

 
Maximum permissible conductor temperature under service condition is taken at 90 degree celsius